DO9786T-R1 – Panel Mounting Conductivity Transmitter

Brand: Delta OHM S.R.L.

DO9786T-R1 – Panel Mounting Conductivity Transmitter

Brand: Delta OHM S.R.L.
DO9786T-R1 transmitters convert the output of a conductivity electrode with temperature compensation into a 4÷20 mA signal.

Housing dimensions 96 x 96 mm for panel mounting with dual LCD (measurement + temperature), output 4…20mA.

The cell constant, the range and the temperature coefficient are completely configurable. 2-wire passive transmitter or 4-wire active transmitter.

Power supply in active mode 24Vac, on request 230Vac, in passive mode 10…35Vdc.

The electrode input circuit is galvanically insulated against the 4÷20 mA output signal.

The LCD indicator allows viewing of the process signal value and of the various parameters.

The accurate design and choice of components make the instrument precise and reliable for a long working life.

The instrument works in conjunction with a conductivity electrode and a temperature probe (Pt100 sensor, 100 Ω at 0°C).

Specifications

Input Conductivity

  • Input: impedance > 10^12 Ω
  • Cable length: < 50 meters screened (about 5 nF)
  • Accuracy: 0.1 % of Reading ± 1-Digit ± 0.01 % of pH per °C of temperature drift
  • Measuring Range: 0.0…199.9 mS
  • 2/4 electrodes: Configurable cell constant 0.0…199.9 cm-1
  • Transducer Energizing: Square wave 10…1000 mV, 200…1600 Hz, depending on conductivity

Temperature Input

  • Pt100 2/4-Wires: -50…199.9° C
  • Transducer energizing: 0.5 mA DC
  • Cable length: < 10 metres unscreened < 50 metres screened (about 2 nF)
  • Accuracy: 0.2° C ± 0.1 % of Reading ± 0.01° C/°C

Compensation Temperature

  • Automatic: Linear 0.00…4.00 %/°C -50…+200° C
  • Manual: Linear 0.00…4.00 %/°C -50…+200° C
  • None:
  • Reference temperature: 20 or 25° C configurable

Current Output

  • 4…20 mA: Programmable and proportional to conductivity
  • Accuracy: 0.5 % of Reading ± 0.02 mA
  • Insulation: 2500 Vac 1 minute

R Load

  • Load resistance: RLmax = Vdc-10/0,022 RLmax= 636 Ω @ Vdc = 24 Vdc

Relay Output

  • A and B: Bistable, contact 3 A/230 Vac free potential

Power Supply

  • Active:24 Vac (or 230 Vac on request) -15/+10 %, 1 VA, 48…62 Hz
  • Passive: 4…20 mA, 2-Wire configuration, 10…35 V

Case DO9766T

  • External dimensions: 120 x 122 x 56 mm (use on the field)
  • Protection class: IP64

Case DO9786T

  • External dimensions: 96 x 96 x 126 mm (panel mounting)
  • Protection class: IP44

14 models matching criteria
Conductivity Transmitter 4…20 mA Passive or Active. For Panel Mounting
Out of Stock
Temperature Probe For Industrial Use, Pt100 Sensor, Shaft Ø6 x 45 mm.
Out of Stock
Temperature Probe With Pt100 Sensor, DIN B Head, Stem Length 600 mm.
Out of Stock
Combined Conductivity And Temperature Probe With 2 Stainless Steel AISI316 Electrodes, Cell Constant 0.01 show more
Combined conductivity and temperature probe with 2 stainless steel AISI316 electrodes, cell constant 0.01. Probe measuring range 0.04…20 μS, 0…120 °C. 4-pole connector. Supplied with cable with 4-pole connector on one side and free wires on the other side.
Out of Stock
Cell Constant K= 0.7, 1.5 m Cable, Temperature Working Range 0…90°C. show more
4-electrode combined conductivity and temperature probe with Pt100 sensor. Cell constant K= 0.7, 1.5 m cable, temperature working range 0…90°C.
Out of Stock
Cell Constant K = 1, Temperature Working Range 0…100 °C. show more
Industrial conductivity probe in glass with 2 platinum electrodes, S7 - PG13.5 connector, cell constant K = 1, temperature working range 0…100 °C.
Out of Stock
Cell Constant K = 1, 2-wire Pt100, Temperature Working Range 0…80 °C. show more
Combined industrial conductivity and temperature probe in Rytron with 2 platinum electrodes, 3/4” BSP connector, 5 m cable, cell constant K = 1, 2-wire Pt100, temperature working range 0…80 °C.
Out of Stock
Cell Constant K = 0.1, 4-wire Pt100, Temperature Working Range 0…80 °C. show more
Combined industrial conductivity and temperature probe in Rytron with 2 platinum electrodes, 3/4” BSP connector, 5 m cable, cell constant K = 0.1, 4-wire Pt100, temperature working range 0…80 °C.
Out of Stock
5 m Extension Cable For Connecting The Electrode To The Transmitter. S7 On One Side, Wires On The Other Side.
Out of Stock
10 m Extension Cable For Connecting The Electrode To The Transmitter. S7 On One Side, Wires On The Other Side.
Out of Stock
Conductivity Transmitter 4…20 mA Passive or Active. For Use On The Field
Out of Stock
ACCREDIA ISO 17025 Certified Standard Solutions Kit show more
ACCREDIA ISO 17025 certified standard solutions kit: 0.001mol/l (147 μS/cm @ 25 °C) + 0.01mol/l (1413 μS/cm @ 25 °C) + 0.1mol/l (12880 μS/cm @ 25 °C). Two 50 ml bottles for each type (6 bottles in total).
Out of Stock
20 m Extension Cable For Connecting The Electrode To The Transmitter. S7 On One Side, Wires On The Other Side.
Out of Stock
Cell Constant K = 10, 4-wire Pt100, Temperature Working Range 0…80 °C. show more
Combined industrial conductivity and temperature probe in Rytron with 2 platinum electrodes, 3/4” BSP connector, 5 m cable, cell constant K = 10, 4-wire Pt100, temperature working range 0…80 °C.
Out of Stock

Documentation

show more