20 m Extension Cable For Connecting The Electrode To The Transmitter. S7 On One Side, Wires On The Other Side.

Price
Request a Quote
Stock
Out of Stock

Specifications

Input Conductivity

  • Input: impedance > 10^12 Ω
  • Cable length: < 50 meters screened (about 5 nF)
  • Accuracy: 0.1 % of Reading ± 1-Digit ± 0.01 % of pH per °C of temperature drift
  • Measuring Range: 0.0…199.9 mS
  • 2/4 electrodes: Configurable cell constant 0.0…199.9 cm-1
  • Transducer Energizing: Square wave 10…1000 mV, 200…1600 Hz, depending on conductivity

Temperature Input

  • Pt100 2/4-Wires: -50…199.9° C
  • Transducer energizing: 0.5 mA DC
  • Cable length: < 10 metres unscreened < 50 metres screened (about 2 nF)
  • Accuracy: 0.2° C ± 0.1 % of Reading ± 0.01° C/°C

Compensation Temperature

  • Automatic: Linear 0.00…4.00 %/°C -50…+200° C
  • Manual: Linear 0.00…4.00 %/°C -50…+200° C
  • None:
  • Reference temperature: 20 or 25° C configurable

Current Output

  • 4…20 mA: Programmable and proportional to conductivity
  • Accuracy: 0.5 % of Reading ± 0.02 mA
  • Insulation: 2500 Vac 1 minute

R Load

  • Load resistance: RLmax = Vdc-10/0,022 RLmax= 636 Ω @ Vdc = 24 Vdc

Relay Output

  • A and B: Bistable, contact 3 A/230 Vac free potential

Power Supply

  • Active:24 Vac (or 230 Vac on request) -15/+10 %, 1 VA, 48…62 Hz
  • Passive: 4…20 mA, 2-Wire configuration, 10…35 V

Case DO9766T

  • External dimensions: 120 x 122 x 56 mm (use on the field)
  • Protection class: IP64

Case DO9786T

  • External dimensions: 96 x 96 x 126 mm (panel mounting)
  • Protection class: IP44

Documentation

Similar SKUs

CP5T
CP5T
DO9785T – pH or mV Configurable Transmitters
Delta OHM
Request a Quote
Out of Stock
5 m Extension Cable For Connecting The Electrode To The Transmitter. S7 On One Side, Wires On The Other Side.
CP5/10T
CP5/10T
DO9785T – pH or mV Configurable Transmitters
Delta OHM
Request a Quote
Out of Stock
10 m Extension Cable For Connecting The Electrode To The Transmitter. S7 On One Side, Wires On The Other Side.
CP
CP
DO9785T – pH or mV Configurable Transmitters
Delta OHM
Request a Quote
Out of Stock
Extension Cable For Connecting The Electrode To The DO9785 (BNC-S7) L = 1.5 m.
CP5T
CP5T
DO9786T-R1 – Panel Mounting Conductivity Transmitter
Delta OHM
Request a Quote
Out of Stock
5 m Extension Cable For Connecting The Electrode To The Transmitter. S7 On One Side, Wires On The Other Side.
CP5/10T
CP5/10T
DO9786T-R1 – Panel Mounting Conductivity Transmitter
Delta OHM
Request a Quote
Out of Stock
10 m Extension Cable For Connecting The Electrode To The Transmitter. S7 On One Side, Wires On The Other Side.
CP5/20T
CP5/20T
DO9785T – pH or mV Configurable Transmitters
Delta OHM
Request a Quote
Out of Stock
20 m Extension Cable For Connecting The Electrode To The Transmitter. S7 On One Side, Wires On The Other Side.
CP
CP
CP Series Extension Cables
Delta OHM
Request a Quote
Out of Stock
Extension Cable For Connecting The Electrode To The DO9785 (BNC‑S7) L= 1.5 m.
CP51.15
CP51.15
CP51 Series – Connecting Cables
Delta OHM
Request a Quote
Out of Stock
Connecting cable with movable 19-pole M23 female connector on one side, open wires on the other side. Length 15m.
show more