HD35AP – Wireless Data Logger System

Brand: Delta OHM S.R.L.

HD35AP – Wireless Data Logger System

Brand: Delta OHM S.R.L.
HD35AP the base unit is the interface between the data loggers of the system, placed in the measurement sites, and the PC.

It communicates wirelessly with the remote data loggers.

When connected to the PC via the USB connection, the base unit is directly powered by the PC USB port.

In the absence of the USB connection, the power is supplied by the internal rechargeable battery or by the external power adapter (optional).

The use of the external power adapter is necessary with the HD35APW and HD35APG/HD35AP3G versions.

Specifications

Pt100 / Pt1000 Measuring Range

  • -200 to +650° C

Pt100 / Pt1000 Resolution

  • 0.1° C

Pt100 / Pt1000 Accuracy

  • ± 0.1° C (excluding probe error)

Pt100 / Pt1000 Sensor Coefficient

  • a=0.00385°C-1

Pt100 / Pt1000 Connection

  • 2, 3 or 4-Wires

Thermocouple Type

  • K, J, T, N, E.
  • The inputs are not isolated, use thermocouples with isolated hot junction

Thermocouple Measuring Range

  • Type K: -200 to +1370° C
  • Type T: -200 to +400° C
  • Type E: -200 to +750° C
  • Type J: -100 to +750° C
  • Type N: -200 to +1300° C

Thermocouple Accuracy (Excluding Probe Error)

  • Type K: ± 0.1° C (600° C)
  • Type J: ± 0.1° C
  • Type T: ± 0.1° C
  • Type N: ± 0.1° C (600° C)
  • Type E: ± 0.1° C (300° C)

Thermocouple Resolution

  • 0.1° C

0/4 to 20 mA Input Shunt Resistance

  • Internal (50 W)

0/4 to 20 mA Input Resolution

  • 16 bits

0/4 to 20 mA Input Accuracy

  • ± 2 µA

0 to 50 mV, 0 to 1 V and 0 to 10 V Inputs (0 to 10 V only in HD35EDWH) Input Resistance

  • 100 MW

0 to 50 mV, 0 to 1 V and 0 to 10 V Inputs (0 to 10 V only in HD35EDWH) Resolution

  • 16 bits

0 to 50 mV, 0 to 1 V and 0 to 10 V Inputs (0 to 10 V only in HD35EDWH) Accuracy

  • ± 0.01 % Full Scale

Input for Counting the Switchings of a Voltage-Free Contact Switching Frequency

  • 50 Hz max

Input for Counting the Switchings of a Voltage-Free Contact Hold Time

  • 10 ms min.

Potentiometer

  • Typically 10 kW

Potentiometer Resolution

  • 16 bits

Potentiometer Accuracy

  • ± 0,01 % Full Scale

11 models matching criteria
With the USB output only
Out of Stock
With the USB output only. “Dongle” version powered only by the PC USB port (without internal battery and without input for the external power supply).
Out of Stock
USB Output / RS485 Output with MODBUS-RTU protocol
Out of Stock
USB Output / Wifi Interface / Ethernet Interface
Out of Stock
Version for 35 mm DIN rail, with: USB Output / RS485 output with MODBUS-RTU Protocol / Ethernet Interface
Out of Stock
USB Output / Integrated GSM/GPRS Module
Out of Stock
USB Output / Integrated GSM/GPRS Module
Out of Stock
USB Output / Integrated 3G/GSM/GPRS Module
Out of Stock
USB Output / 3G/GSM/GPRS Module
Out of Stock
USB Output / Integrated 4G/GSM/GPRS Module
Out of Stock
USB Output / 4G/GSM/GPRS Module
Out of Stock

  • Food and Warehouses
  • Pharmaceutical, Medical Laboratories, Clean Rooms
  • Museums, Buildings and Public places
  • Air Conditioning
  • Renewable Energy
  • Agriculture and Greenhouses
  • Meteorology and Hydrology
  • Industrial Processes
show more