Version for 35 mm DIN rail, with: USB Output / RS485 output with MODBUS-RTU Protocol / Ethernet Interface

Price
Request a Quote
Stock
Contact for Availability

Specifications

Pt100 / Pt1000 Measuring Range

  • -200 to +650° C

Pt100 / Pt1000 Resolution

  • 0.1° C

Pt100 / Pt1000 Accuracy

  • ± 0.1° C (excluding probe error)

Pt100 / Pt1000 Sensor Coefficient

  • a=0.00385° Cˉ¹

Pt100 / Pt1000 Connection

  • 2, 3 or 4-Wires

Thermocouple Type

  • K, J, T, N, E.
  • The inputs are not isolated, use thermocouples with isolated hot junction

Thermocouple Measuring Range

  • Type K: -200° to +1370° C
  • Type T: -200° to +400° C
  • Type E: -200° to +750° C
  • Type J: -100° to +750° C
  • Type N: -200° to +1300° C

Thermocouple Accuracy (Excluding Probe Error)

  • Type K: ± 0.1° C (600° C)
  • Type J: ± 0.1° C
  • Type T: ± 0.1° C
  • Type N: ± 0.1° C (600° C)
  • Type E: ± 0.1° C (300° C)

Thermocouple Resolution

  • 0.1° C

0/4 to 20 mA Input Shunt Resistance

  • Internal (50 W)

0/4 to 20 mA Input Resolution

  • 16-bits

0/4 to 20 mA Input Accuracy

  • ± 2 µA

0 to 50 mV, 0 to 1 V and 0 to 10 V Inputs (0 to 10 V only in HD35EDWH) Input Resistance

  • 100 MW

0 to 50 mV, 0 to 1 V and 0 to 10 V Inputs (0 to 10 V only in HD35EDWH) Resolution

  • 16-bits

0 to 50 mV, 0 to 1 V and 0 to 10 V Inputs (0 to 10 V only in HD35EDWH) Accuracy

  • ± 0.01 % Full Scale

Input for Counting the Switchings of a Voltage-Free Contact Switching Frequency

  • 50 Hz max

Input for Counting the Switchings of a Voltage-Free Contact Hold Time

  • 10 ms min.

Potentiometer

  • Typically 10 kW

Potentiometer Resolution

  • 16-bits

Potentiometer Accuracy

  • ± 0,01 % Full Scale

Similar SKUs

X20EM1612
X20EM1612
X20 System
B&R Industrial Automation
Request a Quote
Out of Stock
X20 Embedded PLC, Atom 0.8 GHz, 768 MB DDR4 RAM, 64 kB FRAM, 1 GB onboard flash drive, 1 insert slot for X20 interface modules, 2 USB interfaces, 1 RS485 interface, 1 POWERLINK interface, 1 Ethernet interface 10/100BASE-T
HD50CR
HD50CR
HD50CR – Clean Room Logger Transmitter
Delta OHM
Request a Quote
Out of Stock
Relative or Differential Low Pressure Transmitter and Data Logger Designed for Wall Flush-Mounting. RS485 Modbus-RTU and Ethernet Output.
HD50CR-AS
HD50CR-AS
HD50CR – Clean Room Logger Transmitter
Delta OHM
Request a Quote
Out of Stock
Relative or Differential Low Pressure Transmitter and Data Logger Designed for Wall Flush-Mounting. RS485 Modbus-RTU Output.
LPPAR03BLS
LPPAR03BLS
LPPAR03 Series – Radiometric Probe for Photons Flow
Delta OHM
Request a Quote
Out of Stock
RS485 MODBUS-RTU Output, Base With Levelling Device
LPPIRG01S
LPPIRG01S
LPPIRG01 – Pyrgeometer for Far Infrared Radiation
Delta OHM
Request a Quote
Out of Stock
Pyrgeometer for Far Infrared Radiation (FIR) measurement With RS485 Modbus-RTU output
HD35APD
HD35APD
HD35AP – Wireless Data Logger System
Delta OHM
Request a Quote
Out of Stock
With the USB output only. “Dongle” version powered only by the PC USB port (without internal battery and without input for the external power supply).
HD35APS
HD35APS
HD35AP – Wireless Data Logger System
Delta OHM
Request a Quote
Out of Stock
USB Output / RS485 Output with MODBUS-RTU protocol
HD35APW
HD35APW
HD35AP – Wireless Data Logger System
Delta OHM
Request a Quote
Out of Stock
USB Output / Wifi Interface / Ethernet Interface
show more