HD2102 – Portable Luxmeter

Brand: Delta OHM S.R.L.
Does not ship to Washington, United States

Portable handheld luxmeter for measuring illuminance, luminance, PAR, irradiance (across VIS-NIR, UVA, UVB and UVC spectral regions or measurement of irradiance effective according to the UV action curve).

In addition to instantaneous measurement, the instrument calculates the acquired measurements time integral Q(t).

Storage of maximum, minimum, average value and the integral Q(t). RS232 C output for data transfer in real time to a PC or printer.

Functions: REL, HOLD and auto power off which can be disabled, IP 66 protection degree.

Includes DeltaLog9 software downloadable here. Supplied with carrying case, instruction manual, 4 batteries.

LP471 probes with SICRAM module are suitable. The probes and cables for data download have to be ordered separately.

Available as well with datalogging function HD2102.2.

Specifications

Measured Quantities

  • lux - fcd - lux/s - fcd/s - W/m2 - µW/cm2 J/m2 - µJ/cm2 - µmol/(m2 . s) - µmol/m2 - cd/m2 - µW/lumen

Batteries

  • Four 1.5 V type AA batteries

Autonomy

  • 200 hours with 1800 mAh alkaline batteries

Power Absorbed with Instrument Off

  • 20 μA

Mains (SWD10)

  • Output mains adapter 12 Vdc / 1A

Security of Memorized Data

  • Unlimited, independent of battery charge conditions

Measured Values Storage - Model HD2102.2 Type (For Single Probes)

  • 2000 pages containing 19 samples each

Measured Values Storage - Model HD2102.2 Type (For Combined Probes)

  • 2000 pages containing 7 samples each

Measured Values Storage - Model HD2102.2 Quantity (For Single Probes)

  • Total of 38000 samples

Measured Values Storage - Model HD2102.2 Quantity (For Combined Probes)

  • Total of 14000 samples

Measured Values Storage - Model HD2102.2 Selectable Storage Interval

  • 1, 5, 10, 15, 30 s
  • 1, 2, 5, 10, 15, 20, 30 min
  • 1 hour

Serial Interface RS-232C Type

  • RS-232C electrically isolated

Baud Rate

  • can be set from 1200 to 38400 baud

Data bit

  • 8

Parity

  • None

Stop bit

  • 1

Flow Control

  • Xon/Xoff

Serial Cable Length

  • Maximum 15 m

Print Interval

  • 1, 5, 10, 15, 30 s
  • 1, 2, 5, 10, 15, 20, 30 min
  • 1 hour

USB Interface - Model HD2102.2 Type

  • 1.1 - 2.0 electrically isolated

Input Module for the Probes

  • 8-Pole Male DIN 45326 Connector

RS-232 Serial Interface

  • 8-Pole MiniDin Connector

USB Serial Interface

  • B-type MiniUSB connector

Mains Adapter

  • 2-Pole Connector (positive at centre)

Date and Time

  • in real time

Accuracy

  • 1 min/month max drift

Working Temperature

  • -5…50° C

Storage Temperature

  • -25…65° C

Working Relative Humidity

  • 0…90 % RH without condensation

Protection Degree

  • IP66

Dimensions (Length x Width x Height)

  • 185 x 90 x 40 mm

Weight

  • 470 g (complete with batteries)

Material

  • ABS, rubber

Display

  • 2x4-1/2 digits plus symbols
  • Visible area: 52 x 42 mm