With RS485 MODBUS-RTU Output

Price
Request a Quote
Stock
Out of Stock

Specifications

Operating Temperature

  • -40…+80° C

Output

  • HD9008TRR, HD9008T7AC, HD9009TRR: analog
  • HD9008T17S, HD9008T7S: RS-485 Modbus-RTU

Power Supply

  • HD9008TRR, HD9008T7AC: 10…30 Vdc
  • HD9008T17S, HD9008T7S: 5…30 Vdc
  • HD9009TRR: 5…35 Vdc

Humidity Sensor

  • HD9008TRR, HD9008T17S, : Capacitive

Humidity Measuring Range

  • HD9008TRR, HD9008T17S, HD9009TRR: 0…100 %RH

Humidity Accuracy

  • HD9008TRR, HD9008T17S, HD9009TRR: ± 1,5 % (0…90 %RH) / ± 2 % (90…100 %RH) @ T=15…35° C ± (1,5 + 1,5 % of the measure) % @ T= remaining range

Humidity Accuracy Response Time

  • HD9008TRR, HD9008T17S, HD9009TRR:< 15 s @ 23° C (air speed = 1 m/s without filter)

Humidity Output Signal

  • HD9008TRR: 0 % RH = 4.0 mA, 100 % RH = 20.0 mA
  • HD9008T17S: RS-485 Modbus-RTU
  • HD9009TRR: 0 %RH = 0.00 Vdc, 100 %RH = 1.00 Vdc

Humidity Load Resistance

  • HD9008TRR: RLmax= (Vdc - 10)/ 22 mA
  • HD9009TRR: RinMIN=10kΩ

Temperature Measuring Range - Standard

  • 40…+80° C

Temperature Accuracy

  • ± 0,2° C ± 0,15 % of the measure

Temperature Response Time

  • < 15 s (without filter)

Temperature Output Signal

  • HD9008TRR, HD9008T7AC:0 % RH = 4.0 mA, 100 % RH = 20.0 mA

Temperature Load Resistance

  • HD9008TRR: RLmax= (Vdc - 10)/ 22 mA

Dimensions

  • Ø 26 x 185 mm

Cable Dimensions Maximum Length for Analog Output Connection

  • HD9008TRR, HD9008T7AC:200 m
  • HD9008T17S, HD9008T7S: depending on Baud Rate and wire gauge
  • HD9009TRR:10 m

Cable Dimensions Wire Minimum Section

  • 20 AWG - 0.5 mm2

Cable Dimensions Cable Maximum Diameter

  • Ø 5 mm

Documentation

Similar SKUs

HD50CR
HD50CR
HD50CR – Clean Room Logger Transmitter
Delta OHM
Request a Quote
Out of Stock
Relative or Differential Low Pressure Transmitter and Data Logger Designed for Wall Flush-Mounting. RS485 Modbus-RTU and Ethernet Output.
HD9817TVS
HD9817TVS
HD9817T… Series – RH and Temperature Digital Transmitters
Delta OHM
Request a Quote
Out of Stock
Dual Temperature and Relative Humidity Transmitter. Pt100 Sensor. 0…1 Vdc Analog Outputs and RS485 MODBUS-RTU Output
LPPAR03BLS
LPPAR03BLS
LPPAR03 Series – Radiometric Probe for Photons Flow
Delta OHM
Request a Quote
Out of Stock
RS485 MODBUS-RTU Output, Base With Levelling Device
LPPIRG01S
LPPIRG01S
LPPIRG01 – Pyrgeometer for Far Infrared Radiation
Delta OHM
Request a Quote
Out of Stock
Pyrgeometer for Far Infrared Radiation (FIR) measurement With RS485 Modbus-RTU output
HD3910.2.10
HD3910.2.10
HD3910 – Soil Volumetric Water Content
Delta OHM
Request a Quote
Out of Stock
Three-electrode probe for the measurement of the soil volumetric water content. RS485 MODBUS RTU output. Cable length 10 m.
HD3910.2.5
HD3910.2.5
HD3910 – Soil Volumetric Water Content
Delta OHM
Request a Quote
Out of Stock
Three-electrode probe for the measurement of the soil volumetric water content. RS485 MODBUS RTU output. Cable length 5 m.
HD35APS
HD35APS
HD35AP – Wireless Data Logger System
Delta OHM
Request a Quote
Out of Stock
USB Output / RS485 Output with MODBUS-RTU protocol
HD35APR
HD35APR
HD35AP – Wireless Data Logger System
Delta OHM
Request a Quote
Out of Stock
Version for 35 mm DIN rail, with: USB Output / RS485 output with MODBUS-RTU Protocol / Ethernet Interface
show more