Price
Request a Quote
Stock
Out of Stock

  • Transmitter - Standard Transmitter

Specifications

Accuracy

  • (mA Output/2,000) or 5 µA whichever is greater, Drift 1 µA/°C
  • ± 0.02 % of Full Scale (-100 to 200 mV)
  • ± 0.1 % of Full Scale ± 0.5° C (± 0.9° F) (Plus Sensor Error)
  • ± 0.2 % of Full Scale ± 0.5° C (± 0.9° F) (Plus Sensor Error)

Ambient Temperature Range

  • Configuration Ambient: 10° to 30° C (50° to 86° F)

Approvals & Certifications

  • ATEX - CE II 1 GD, Ex ia IIC T4 Ga, Ex iaD 20 T1 35° C Da, Tamp = 40° to 85° C
  • CE - BS EN 61326

Burn-Out

  • Downscale - 3.8 mA
  • Up Scale - 21.5 mA

Communication

  • Baud Rate: 1,200 bit/sec
  • USB 2.0

Connection Style

  • Screw Terminals

Current

  • Excitation Current: < 200 UA

Environmental Protection

  • IP65

Humidity

  • 10 to 90 % Relative Humidity, Non-Condensing

Input

  • -100 to 200 mV

Isolation

  • Input to Output: 500 Vdc

Linearization

  • (2 to 22) Segments mV to Process

Mounting

  • Head Mount

Operating Temperature

  • Operating Ambient Temperature: -40° to 85° C (-40° to 185° F)

Output

  • 2-Wire
  • 4-20 mA Current Loop

Output Load

  • (Vsupply-10)/20 kiloohms

Power Supply

  • < 1 W Full Power
  • 10-30 Vdc

Response Time

  • 500 milliseconds
  • Start Up: 5 seconds

Sensor, Probe Connection

  • Screw Terminal 2.5 mm, Max.

Sensor, Probe Diameter

  • 1.69” (43 mm)

Sensor, Probe Type

  • B Thermocouple
  • C Thermocouple
  • D Thermocouple
  • E Thermocouple
  • J Thermocouple
  • K Thermocouple
  • L Thermocouple
  • N Thermocouple
  • R Thermocouple
  • T Thermocouple
  • U Thermocouple
  • W Thermocouple

Storage Temperature

  • Ambient Storage Temperature: -50° to 85° C (-58° to 185° F)

System Requirements

  • Windows® XP

Temperature Range

  • Cold Junction: -40° to 85° C (-40° to 185° F)
  • Thermocouple: -200° to 2,300° C (-328° to 4,172° F)

Thermal Drift

  • 1 µA/°C
  • Thermocouple Offset: 0.1° C/°C

Update Time

  • 160 milliseconds
  • Warm-Up: 2 minutes

show more