Barometric transmitter to wall mount for indoor use, with 0 to 1 Vdc analog output. Measuring range 600 to 1100mbar.

Price
Request a Quote
Stock
Out of Stock

Specifications

Type of Sensor

  • Piezoresistive

Measurement Range

  • 600 to 1100 mbar

Analog Output

  • 0 to 1 Vdc

Accuracy

  • ± 0.5 mbar, @ 20° C

Resolution

  • Infinite

Temperature Drift

  • < 1 % Full Scale, zero
  • < 1 % Full Scale, span
  • From -20° C to +60° C (-4° F to 140° F)

Long Term Stability

  • < 0.25 % Full Scale at 6 months at 20° C

Setting Time

  • 1 sec. to 99 % of the measure

Response Time

  • < 200 ms after pressure stabilization

Power Supply

  • 10 to 40 Vdc

Current Supply

  • < 4 mA

Working Temperature

  • -30° to +60° C

Compatibility Media

  • Only air and non aggressive dry gases

Overpressure

  • 2 bar - 30 psi

Dimensions

  • 60 x 66 x 35 mm

Weight

  • 100 g

Documentation

Similar SKUs

HD50CR-AS
HD50CR-AS
HD50CR – Clean Room Logger Transmitter
Delta OHM
Request a Quote
Out of Stock
Relative or Differential Low Pressure Transmitter and Data Logger Designed for Wall Flush-Mounting. RS485 Modbus-RTU Output.
HD9817TVS
HD9817TVS
HD9817T… Series – RH and Temperature Digital Transmitters
Delta OHM
Request a Quote
Out of Stock
Dual Temperature and Relative Humidity Transmitter. Pt100 Sensor. 0…1 Vdc Analog Outputs and RS485 MODBUS-RTU Output
HD2021T6.AV
HD2021T6.AV
HD2021T6 / HD2021T7 – Photometric Radiometric Transmitters
Delta OHM
Request a Quote
Out of Stock
Transmitter for measuring the LUMINANCE. Amplified with output 0…10Vdc.
HD2021T6.BV
HD2021T6.BV
HD2021T6 / HD2021T7 – Photometric Radiometric Transmitters
Delta OHM
Request a Quote
Out of Stock
Transmitter for measuring the LUMINANCE. Amplified with output 0…10Vdc.
HD2021T6.CV
HD2021T6.CV
HD2021T6 / HD2021T7 – Photometric Radiometric Transmitters
Delta OHM
Request a Quote
Out of Stock
Transmitter for measuring the LUMINANCE. Amplified with output 0…10Vdc.
HD2021T7.2.AV
HD2021T7.2.AV
HD2021T6 / HD2021T7 – Photometric Radiometric Transmitters
Delta OHM
Request a Quote
Out of Stock
Transmitter for measuring the LUMINANCE by a 2° angle. Amplified with output 0…10Vdc.
HD2021T7.AV
HD2021T7.AV
HD2021T6 / HD2021T7 – Photometric Radiometric Transmitters
Delta OHM
Request a Quote
Out of Stock
Transmitter for measuring the LUMINANCE of equivalent veiling. Amplified with output 0…10Vdc.
HD2021T7.BV
HD2021T7.BV
HD2021T6 / HD2021T7 – Photometric Radiometric Transmitters
Delta OHM
Request a Quote
Out of Stock
Transmitter for measuring the LUMINANCE of equivalent veiling. Amplified with output 0…10Vdc.
show more