Panel mounting conductivity transmitter with dual LCD, output 4...20 mA. Power supply active mode 230 Vac.

Price
Request a Quote
Stock
Out of Stock

Specifications

Input Conductivity

  • Input: impedance > 10^12 Ω
  • Cable length: < 50 meters screened (about 5 nF)
  • Accuracy: 0.1 % of Reading ± 1-Digit ± 0.01 % of pH per °C of temperature drift
  • Measuring Range: 0.0…199.9 mS
  • 2/4 electrodes: Configurable cell constant 0.0…199.9 cm-1
  • Transducer Energizing: Square wave 10…1000 mV, 200…1600 Hz, depending on conductivity

Temperature Input

  • Pt100 2/4-Wires: -50…199.9° C
  • Transducer energizing: 0.5 mA DC
  • Cable length: < 10 metres unscreened < 50 metres screened (about 2 nF)
  • Accuracy: 0.2° C ± 0.1 % of Reading ± 0.01° C/°C

Compensation Temperature

  • Automatic: Linear 0.00…4.00 %/°C -50…+200° C
  • Manual: Linear 0.00…4.00 %/°C -50…+200° C
  • None:
  • Reference temperature: 20 or 25° C configurable

Current Output

  • 4…20 mA: Programmable and proportional to conductivity
  • Accuracy: 0.5 % of Reading ± 0.02 mA
  • Insulation: 2500 Vac 1 minute

R Load

  • Load resistance: RLmax = Vdc-10/0,022 RLmax= 636 Ω @ Vdc = 24 Vdc

Relay Output

  • A and B: Bistable, contact 3 A/230 Vac free potential

Power Supply

  • Active:24 Vac (or 230 Vac on request) -15/+10 %, 1 VA, 48…62 Hz
  • Passive: 4…20 mA, 2-Wire configuration, 10…35 V

Case DO9766T

  • External dimensions: 120 x 122 x 56 mm (use on the field)
  • Protection class: IP64

Case DO9786T

  • External dimensions: 96 x 96 x 126 mm (panel mounting)
  • Protection class: IP44

Documentation

Similar SKUs

DO9786T-R1
DO9786T-R1
DO9786T-R1 – Panel Mounting Conductivity Transmitter
Delta OHM
Request a Quote
Out of Stock
Conductivity Transmitter 4…20 mA Passive or Active. For Panel Mounting
DO9766T-R1
DO9766T-R1
DO9786T-R1 – Panel Mounting Conductivity Transmitter
Delta OHM
Request a Quote
Out of Stock
Conductivity Transmitter 4…20 mA Passive or Active. For Use On The Field
DO9403T-R1
DO9403T-R1
DO9403T-R1 – pH / mV Transmitter
Delta OHM
Request a Quote
Out of Stock
pH or mV transmitter, completely configurable, output 4...20 mA insulated with 2 wires passive or 4 wires active, power supply active mode 24 Vac.
DO9403TR-R1
DO9403TR-R1
DO9403T-R1 – pH / mV Transmitter
Delta OHM
Request a Quote
Out of Stock
pH or mV transmitter, completely configurable, output 4...20 mA insulated with 2 wires passive or 4 wires active, power supply active mode 230 Vac.
DO9785TR
DO9785TR
DO9785T, DO9765T – pH or mV Configurable Transmitters
Delta OHM
Request a Quote
Out of Stock
Panel mounting pH or mV configurable, dual LCD, output 4...20mA insulated with 2 wires passive or with 4 wires active. Power supply active mode 230 Vac.
DO9766T-R1
DO9766T-R1
DO9766T-R1, DO9786T-R1 – Conductivity Transmitter
Delta OHM
Request a Quote
Out of Stock
Conductivity transmitter, housing with dual LCD, output 4...20 mA. Power supply active mode 24 Vac.
DO9766TR-R1
DO9766TR-R1
DO9766T-R1, DO9786T-R1 – Conductivity Transmitter
Delta OHM
Request a Quote
Out of Stock
Conductivity transmitter, housing with dual LCD, output 4...20 mA. Power supply active mode 230 Vac.
DO9786T-R1
DO9786T-R1
DO9766T-R1, DO9786T-R1 – Conductivity Transmitter
Delta OHM
Request a Quote
Out of Stock
Panel mounting conductivity transmitter with dual LCD, output 4...20 mA. Power supply active mode 24 Vac.
show more