Spare Wired Protective Sphere.

Price
Request a Quote
Stock
Contact for Availability

Specifications

Air Speed Measuring Range

  • 0.1…5 m/s

Air Speed Accuracy

  • range 0.1…0.99 m/s: ± 0.1 m/s
  • range 1…5 m/s: ± 0.4 m/s

Temperature Measuring Range

  • -10 to +80° C

Temperature Accuracy

  • range 0 to 70° C: ± 0.3° C
  • remaining range: ± 0.4° C

Output (For Temp and Air Speed)

  • 4…20 mA
  • 0…20 mA
  • 0…10 Vdc

Load Resistance

  • 100 kΩ, for voltage outputs

Power Supply

  • 24 Vac ± 10 %, 50/60 Hz
  • 110 Vac or 230 Vac on request

Operating Temperature

  • Electronics:-5° to +50° C
  • probe: -10° to +80° C

Compensation Temperature

  • -0 to +80° C

Storage Temperature

  • -10 to +80° C

Electronics Protection Class

  • IP67

Sensor Working Conditions

  • Clean air, RH< 80 %

Case Dimensions

  • 120 x 80 x 55

Probe Cable Length

  • L=5 m

Documentation

Similar SKUs

0TB1210.3100
0TB1210.3100
Panel PC 2200 (AP5000) swing arm, single-touch
B&R Industrial Automation
Request a Quote
Out of Stock
Connector 300 VDC - 10-pin female - Cage clamp terminal block - Protected against vibration by the screw flange
0TB3103.8000
0TB3103.8000
Panel PC 900 Multi-Touch
B&R Industrial Automation
Request a Quote
Out of Stock
Connector 230 VAC - 3-pin female - Screw clamp terminal block 4 mm² - Protected against vibration by the screw flange
1TGMPAUDIT.10-01
1TGMPAUDIT.10-01
Panel PC 900 Multi-Touch
B&R Industrial Automation
Request a Quote
Out of Stock
mapp Audit collects and manages a wide range of different events. These include when user-defined events occur, when machine operators log in/out or when an alarm occurs. All events are collected and can be exported with password protection to protect them from tampering.
HD9007A-1
HD9007A-1
HD9007A… – Ring Shield for Transmitters
Delta OHM
Request a Quote
Out of Stock
12-Ring Protection From Solar Radiations.
HD9007A-2
HD9007A-2
HD9007A… – Ring Shield for Transmitters
Delta OHM
Request a Quote
Out of Stock
16-Ring Protection From Solar Radiations.
HD9007A-3
HD9007A-3
HD9007A… – Ring Shield for Transmitters
Delta OHM
Request a Quote
Out of Stock
6-Ring Protection From Solar Radiations.
DO9765TR
DO9765TR
DO9785T, DO9765T – pH or mV Configurable Transmitters
Delta OHM
Request a Quote
Out of Stock
pH or mV completely configurable, with dual LCD, output 4...20mA insulated with 2 wires passive or 4 wires. Power supply active mode 230 Vac.
HD32.7
HD32.7
HD32.7 – 8 Inputs Temperature Data Logger – Pt100
Delta OHM
Request a Quote
Out of Stock
Data logger with 8 inputs for temperature Pt100 sensor probes equipped with SICRAM module, 4 wires Pt100 and 2 wires Pt1000 probes.
show more