FTK Temperature Calibration Checker

Brand: Calex Electronics Limited

The FTK provides a quick and accurate way to check the calibration of infrared temperature sensors.

This rugged and portable unit is designed to provide fast calibration checks anywhere they are needed, from the factory to the workshop or laboratory.

The FTK takes between 5 and 15 minutes to heat and stabilize at the desired temperature (depending on the model), and uses a clear LED to show when it has reached that temperature: green when the FTK is warming up, orange when the FTK is ready for operation and red when the FTK is above the calibration temperature.

18 models matching criteria
  • Temperature - 75° C (167° F)
Out of Stock
  • Temperature - 60° C (140° F)
Out of Stock
  • Temperature - 130° C (266° F)
Out of Stock
  • Temperature - 45° C (113° F)
Out of Stock
  • Temperature - 100° C (212° F)
Out of Stock
  • Temperature - 65° C (149° F)
Out of Stock
  • Temperature - 110° C (230° F)
Out of Stock
  • Temperature - 90° C (194° F)
Out of Stock
  • Temperature - 120° C (248° F)
Out of Stock
  • Temperature - 50° C (122° F)
Out of Stock
  • Temperature - 150° C (302° F)
Out of Stock
  • Temperature - 80° C (176° F)
Out of Stock
  • Temperature - 95° C (203° F)
Out of Stock
  • Temperature - 85° C (185° F)
Out of Stock
  • Temperature - 55° C (131° F)
Out of Stock
  • Temperature - 140° C (284° F)
Out of Stock
  • Temperature - 70° C (158° F)
Out of Stock
  • Temperature - 35° C (95° F)
Out of Stock

Specifications

Accuracy

  • 0.4° C (0.72° F) at Tamb 10° to 30° C - Temperature Uncertainty (For FTK 35-120)
  • 0.5° C (0.9° F) at Tamb 10° to 40° C - Temperature Uncertainty (For FTK 130-150)
  • 0.6° C (1.08° F) at Tamb 0° to 10° C - Temperature Uncertainty (For FTK 35-120)
  • 0.7° C (1.26° F) at Tamb 0° to 10° C - Temperature Uncertainty (For FTK 130-150)

Approvals & Certifications

  • CE

Diameter

  • 2” (50.8 mm) - Aperture Diameter

Display

  • LED Display (Green, Orange & Red)

Environmental Protection

  • IP50 (EN 60529)

Humidity

  • 10 to 85 % Relative Humidity, Non-Condensing

Mounting

  • Fixed Mounting Bracket

Operating Temperature

  • 0° to 30° C (32° to 86° F), Temporary (2 minutes) up to 70° C (158° F)

Output

  • 24 Vdc at 1.3 A

Power Requirement

  • 100-240 Vac at 50 Hz
  • 24 Vdc, Max.

Repeatability

  • 0.2° C (0.36° F)

Stability

  • 0.1° C (0.18° F)

Storage Temperature

  • 0° to 70° C (32° to 158° F)

Temperature Range

  • 35° to 150° C (95° to 302° F) - Target Temperature

Update Time

  • 5 to 15 minutes, Max.

Show More