HD2128 Thermocouple Thermometer

Brand: Delta OHM S.R.L.
Does not ship to Massachusetts, United States

The HD2108.1 and HD2108.2 with one input and the HD2128.1 and HD2128.2 with two inputs are portable instruments with a large LCD display.

They measure the temperature using immersion, penetration, air or contact probes.

The sensor may be a thermocouple of type K, J, T, N, R, S, B or E.

Instruments HD2108.2 and HD2128.2 are data loggers, they store up to 76.000 samples the first and 38.000 couples of values the second.

These data can be transferred into a PC connected to the instrument through the serial ports RS232C and USB 2.0.

It is possible to configure the storage interval, the printing and the baud rate by the menu.

Functions Max, Min and Avg calculate maximum, minimum and average values.

Further functions are: REL relative measure, HOLD and automatic switching off system (excludable).

HD2128.1 and HD2128.2 calculate A-B difference of the temperatures acquired by the two input channels.

Instruments have IP66 protection degree.

Specifications

TC Measuring Range: K

  • -200…+1370° C

TC Measuring Range: J

  • -100…+750° C

TC Measuring Range: T

  • -200…+400° C

TC Measuring Range: N

  • -200…+1300° C

TC Measuring Range: R

  • +200…+1480° C

TC Measuring Range: S

  • +200…+1480° C

TC Measuring Range: B

  • +200…+1800° C

TC Measuring Range: E

  • -200…+750° C

Resolution

  • 0.05° C in the range ± 199.95° C
  • 0.1° C in the remaing range

Thermocouple K

  • ± 0.1° C up to 600° C
  • ± 0.2° C over 600° C

Thermocouple J

  • ± 0.05° C up to 400° C
  • ± 0.1° C over 400° C

Thermocouple T

  • ± 0.1° C

Thermocouple N

  • ± 0.1° C up to 600° C
  • ± 0.2° C over 600° C

Thermocouple R

  • ± 0.25° C

Thermocouple S

  • ± 0.3° C

Thermocouple B

  • ± 0.35° C

Thermocouple E

  • ± 0.1° C up to 300° C
  • ± 0.15° C over 300° C

Temperature Drift at 20° C

  • 0.02 %/°C

Drift After 1 Year

  • 0.1° C/year

Unit of Measurement

  • °C - °F - K - mV - mV*C

Model HD2108.2

  • 2000 pages each one containing 38 samples, 76000 samples in total

Model HD2128.2

  • 2000 pages each one containing 19 samples, 38000 samples in total

Storage Interval Can be Selected Among

  • 1,5,10,15,30 s,
  • 1,2,5,10,15,20,30 min
  • 1 hour

Security of Stored Data

  • Unlimited, independent of battery charge conditions.

Batteries

  • Four 1.5 V type AA batteries

Autonomy

  • 200 hours with 1800 mAh alkaline batteries

Current Consumption with Instrument of

  • 20 μA

Main

  • 12 Vdc / 1000 mA Output main adapter

Serial Interface RS-232C Type

  • RS-232C galvanically isolated

Baud Rate

  • can be set from 1200 to 38400 baud

Data bit

  • 8

Parity

  • None

Stop bit

  • 1

Flow Control

  • Xon/Xoff

Serial Cable Length

  • Maximum 15 m

Print Interval

  • 1,5,10,15,30 s,
  • 1,2,5,10,15,20,30 min
  • 1 hour

USB Interface Model HD2108.2 and HD2128.2 Type

  • 1.1 - 2.0 galvanically isolated

Probes Input

  • 2-Pole female polarized standard miniature Connector

Serial Interface

  • 8-Pole MiniDin Connector

USB Interface

  • Type B Mini USB connector

Mains Adapter

  • 2-Pole Connector (positive at centre)

Operating Temperature

  • -5...50° C

Storage Temperature

  • -25 … 65° C

Working Relative Humidity

  • 0 … 90 %RH, no condensation

Protection Degree

  • IP66

Dimensions (Length x Width x Height)

  • 185 x 90 x 40 mm

Weight

  • 470 g (complete with batteries)

Materials

  • ABS, rubber

Display

  • 2 rows 4-1/2 digits plus symbols Visible area: 52 x 42 mm

Date and Time

  • in real time

Time Accuracy

  • 1 min/month max drift

Documentation

show more