HD2106 Conductivity-Thermometer

Brand: Delta OHM S.R.L.

HD2106 Conductivity-Thermometer

Brand: Delta OHM S.R.L.
HD2106.1 and HD2106.2 are portable instruments with LCD display. 

They measure conductivity, liquid resistivity, total dissolved solids (TDS), and salinity using combined 4-ring and 2-ring conductivity/ temperature probes. 

Temperature only is measured by Pt100 or Pt1000 immersion, penetration, contact or air probes. 

The probe calibration can be performed automatically in one or more than one of the 147 μS/cm , 1413 μS/cm , 12880 μS/cm  or 111800 μS/cm conductivity calibration solutions. 

The temperature probes are equipped with an automatic recognition module and factory calibration data are stored inside. 

The HD2106.2 is a datalogger. 

It memorizes up to 36,000 conductivity and temperature samples which can be transferred from the instrument connected to a PC via the RS232C and USB 2.0 serial ports. 

The storing interval, printing, and baud rate can be configured using the menu. 

Both models are fitted with an RS232C serial port and can transfer to a PC the acquired measurements or to a portable printer in real time. 

The Max, Min and Avg function calculates the maximum, minimum or average values. 

Other functions include: the relative measurement REL, the AutoHOLD function, and the automatic turning off which can also be excluded. 

The instruments have IP66 protection degree.

Specifications

Measured Quantities

  • χ, Ω, TDS, NaCl, °C, °F

Conductivity Measuring Range Kcell=0.01

  • 0.0000…1.999 μS/cm
  • Resolution: 0.001 μS/cm

Conductivity Measuring Range Kcell=0.1

  • 0.00…19.99 μS/cm
  • Resolution: 0.01 μS/cm

Conductivity Measuring Range Kcell=1

  • 0.0…199.9 μS/cm, Resolution 0.1 μS/cm
  • 200…1999 μS/cm1, Resolution μS/cm
  • 2.00…19.99 mS/cm, Resolution 0.01 mS/cm
  • 20.0…199.9 mS/cm, Resolution 0.1 mS/cm

Conductivity Measuring Range Kcell=10

  • 200…1999 mS/cm
  • Resolution: 1 mS/cm

Accuracy (Conductivity)

  • ± 0.5 % ± 1digit

Resistivity Measuring Range Kcell=0.01

  • till 1 GΩ∙cm

Resistivity Measuring Range Kcell=0.1

  • till 100 MΩ∙cm

Resistivity Measuring Range Kcell=1

  • 5.0…199.9 Ω∙cm, Resolution 0.1 Ω∙cm
  • 200…999 Ω∙cm, Resolution 1 Ω∙cm
  • 1.00 k…19.99 kΩ∙cm, Resolution 0.01 kΩ∙cm
  • 20.0 k…99.9 kΩ∙cm, Resolution 0.1 kΩ∙cm
  • 100 k…999 kΩ∙cm, Resolution 1 kΩ∙cm
  • 1…10 MΩ∙cm, Resolution 1 MΩ∙cm

Resistivity Measuring Range Kcell=10

  • 0.5…5.0 Ω∙cm, Resolution 0.1 Ω∙cm

Accuracy (Resistivity)

  • ± 0.5 % ± 1digit

Dissolved Solids Measuring Range Kcell=0.01

  • 0.000…19.999 mg/L
  • Resolution: 0.005 mg/l

Dissolved Solids Measuring Range Kcell=0.1

  • 0.00…19.99 mg/L 0.05 mg/L
  • Resolution: 0.05 mg/l

Dissolved Solids Measuring Range Kcell=10

  • 100…999 g/l
  • Resolution: 1 g/l

Accuracy (Total Dissolved Solids)

  • ± 0.5 % ± 1digit

Salinity Measurement Range

  • 0.000…1.999 g/L, Resolution 1 mg/L
  • 2.00…19.99 g/l, Resolution 10 mg/l
  • 20.0…199.9 g/l, Resolution 0.1 g/l

20.0…199.9 g/l0.1 g/l

  • ± 0.5 % ± 1digit

Pt100 Measuring Range

  • Pt100 measuring range

Resolution

  • 0.1° C

Accuracy

  • ± 0.25° C

Drift After 1 Year

  • 0.1° C/year

Temperature Compensation Automatic/Manual

  • 0…100° C with αT selectable from 0.00 to 4.00 %/ °C

Reference Temperature

  • 20° C o 25° C

χ / TDS Conversion Factor

  • 0.4…0.8

Preset Cell Constant Values: (cm-1)

  • K=0.01 K=0.1 - K=0.7 - K=1 - K=10

Standard Solutions Automatically Detected at 25° C

  • 147 µS/cm
  • 1413 µS/cm
  • 12880 µS/cm
  • 111800 µS/cm

Batteries

  • Four 1.5 V type AA batteries

Autonomy

  • 200 hours with 1800 mAh alkaline batteries

Power Absorbed with Instrument Off

  • 20 μA

Mains (SWD10)

  • Output mains adapter 12 Vdc / 1A

Security of Memorized Data

  • Unlimited, independent of battery charge conditions

model HD 2106.2 Type

  • 2000 pages containing 18 samples each

Quantity

  • 36000 pairs of measurements [χ-°C], [Ω-°C], [TDS-°C] or [Sal-°C]

Selectable Storage Interval

  • 1, 5, 10, 15, 30 s
  • 1, 2, 5, 10, 15, 20, 30 min
  • 1 hour

Serial Interface RS-232C Type

  • RS-232C electrically isolated

Baud Rate

  • can be set from 1200 to 38400 baud

Data bit

  • 8

Parity

  • None

Stop bit

  • 1

Flow Control

  • Xon/Xoff

Serial Cable Length

  • Maximum 15 m

Print Interval

  • 1, 5, 10, 15, 30 s
  • 1, 2, 5, 10, 15, 20, 30 min
  • 1 hour

USB Interface - Model HD 2106.2 Type

  • 1.1 - 2.0 electrically isolated

Temperature Input

  • 8-Pole Male DIN 45326 Connector

Conductivity Input

  • 8-Pole Male DIN 45326 Connector

Serial Interface and USB

  • 8-Pole MiniUSB type B

Mains Adapter

  • 2-Pole Connector (positive at centre)

Date and Time

  • in real time

Time Accuracy

  • 1 min/month max error

Working Temperature

  • -5…50° C

Storage Temperature

  • -25…65° C

Working Relative Humidity

  • 0…90 % RH without condensation

Protection Degree

  • IP66

Dimensions (Length x Width x Height)

  • 185 x 90 x 40 mm

Weight

  • 470 g (complete with batteries)

Material

  • ABS, rubber

Display

  • 2 x 4-1/2 digits plus symbols Visible area: 52 x 42 mm

Models matching criteria: 2
Conductivity-Thermometer
Out of Stock
Conductivity-Thermometer Data Logger
Out of Stock

Documentation

show more