SEM1720 Dual Channel Signal Conditioner
Brand: Status InstrumentsSEM1720 Dual Channel Signal Conditioner
Brand: Status InstrumentsSEM1720 is a dual channel signal conditioner designed to accept RTD, Thermocouple or Potentiometer sensors and provide isolated, industrial process output signals in mA or Volts.
Each output channel may be linked to either input sensor or to a maths function of both sensor signals.
This powerful feature allows the device to operate in a number of different modes.
SEM1720 is configured using the free USB SpeedLink software that allows the user to configure the device without requiring calibration equipment.
Maths functions on each channel can be set up using the software as well as a 22 segment profile tool. Input output simulation tools for diagnostic purposes are also available. Thanks
Features- Dual Channel With 5 Port Isolation (3.75Kv)
- Accepts RTD, Thermocouple or Potentiometer Sensors
- Universal Voltage Or Current Outputs
- Maths Functions Between Channels
- Sensor Redundancy Switching
- Eight User Configured Preset Configurations
Specifications
Brand
Accuracy
- ± 0.05 % - Slide Wire for Input (Channels 1 & 2)
- ± 10 µV 1 Reading/second - Thermocouple Input: mV
- ± 5 mV - Voltage Range for Output (Channels 1 & 2)
- 1 Reading/second ± 0.15° C (± 0.27° F) + (0.05 % of Full Scale Reading) - RTD Input
- 1 Reading/second ± 0.5° C (± 0.9° F) + (0.1 % of Full Scale Reading) - Thermocouple Input: K, J, E, N, T, R, S, L, B, U, C, D, G
- Cold Junction: -20 to 70° C ± 0.5° C, Tracking ± 0.05° C/°C
Calibration
- ± 5 µA
Communication
- USB
Connection Style
- Screw Terminal - Output Connection
Current
- 0.5 A - Protection
- 0-20 mA - Full Range
- 0 to 23.1 mA to Max.
Display
- Green LED
- Red LEDs
Humidity
- 10 to 90 % Relative Humidity, Non-Condensing
Indication
- LED
Input
- < 450 µA - Excitation
Input Impedance
- 1 Megaohm
Input Signal
- RTD
- Thermocouples
Isolation
- 3,750 Vdc - Galvanic Isolation Test Voltage - Input Output Ports
- 4,000 Vdc - Galvanic Isolation Test Voltage - Supply to Input/Output
Load
- Voltage Load: Min. 1 Kiloohm
Mounting
- DIN Rail
Operating Temperature
- -20° to 70° C (-4° to 158° F)
Operating Voltages
- 253 Vac - Working Voltage
Output
- 0-10 V - Full Range
- 0 to 10.1 V - Max.
Power
- 3 W at Full Output Current
Power Supply Effect
- 0.2 µA/V (Sink Mode) - Loop Voltage Effect
Range
- -200 to 200 mV
Resistance
- 0 to 1 kiloohms Min.
- 0 to 100 kiloohms Pot, Max.
Response Time
- 200 milliseconds
RTD Type
- Cu100
- Cu53 (GOST)
- Ni100 (DIN)
- Ni120 (Nickel A)
- Pt100 (IEC, IPTS-68, ITS-90)
Sensor, Probe Connection
- 3-Wire
Sensor, Probe Type
- B Thermocouple
- C(W5) Thermocouple
- D(W3) Thermocouple
- E Thermocouple
- G(W) Thermocouple
- J Thermocouple
- K Thermocouple
- L Thermocouple
- N Thermocouple
- R Thermocouple
- S Thermocouple
- T Thermocouple
- U Thermocouple
Stability
- ± 0.015 % of Full Scale Reading/°C - RTD Input
- ± 0.05 % of Full Scale Reading/°C - Thermocouple Input: K, J, E, C(W5), D(W3), G(W), mV
- ± 0.08 % of Full Scale Reading/°C - Thermocouple Input: N, L, U
- ± 0.10 % of Full Scale Reading/°C - Thermocouple Input: R, S, B
- ± 0.15 % of Full Scale Reading/°C - Thermocouple Input: T
- ± 1 μV/°C - Voltage Range for Output (Channels 1 & 2)
- ± 5 μA/°C - Current Range for Output (Channels 1 & 2)
Storage Temperature
- -40° to 85° C (-40° to 185° F)
Supply Voltage
- 10-30 Vdc - Output Current Sink
- 20-240 Vac at 50/60 Hz
- 20-240 Vdc
- 250 Vac - Max.
System Requirements
- Windows® XP
Temperature Range
- -20° to 70° C (-4° to 158° F) ± 0.5° C (0.9° F) - Cold Junction
- -200° to 2,300° C (-328° to 4,172° F)
Turn-On Time
- 4 seconds - Start Up Time
Update Time
- 1 Minute - Warm-Up Time
- 200 milliseconds
Zero Offset
- ± 10° C (± 18° F) - Sensor Offset