SEM1600B Load Cell Signal Conditioner
Brand: Status InstrumentsSEM1600B Load Cell Signal Conditioner
Brand: Status InstrumentsThe SEM1600/B is a “smart” powered bridge amplifier for use with strain gauges or load cell signals.
The product has a built in capability to scale the input signal to a process value while the output stage offers either voltage, bipolar voltage or active / passive current re-transmission signals.
The product comes with an AC/DC power supply that will operate in the range (10-48) Vdc and (10-32) Vac making the device ideal for battery operation.
An additional volt free contact input is available for tare setting using a remote switch.
The high precision input stage of the device allows for a bridge excitation voltage of 5 Vdc to be used as opposed to the traditional 10 Vdc. This reduces the power requirement for the bridge supply and up to four bridges (cells) may be connected to the input.
The device is provided with two front panel push buttons that can be configured to perform one of two functions or be disabled.
Set as function 1, the buttons allow the user to push button configure the output range at high and low scale against a live input signal, set as function 2, the buttons allow the operator to trim the output at high and low scale.
The device uses ratio metric measurement to obtain high stability.
Features- Accepts Up To 4 Load Cells In Parallel
- Output Current or Voltage Signal
- Calibration Function
- Remote Tare Function
- Power Supply (10 to 32) V AC or (10 to 48) V DC Supply
- View Live Data On An Android Phone Or Tablet
Specifications
Brand
Accuracy
- Output Current: (mA Out/2,000) or 5 µA whichever is greater
- Output Voltage: ± 5 mV
Ambient Temperature Range
- 10° to 30° C (50° to 86° F)
Applications
- Load Cell/Strain Gauge
Approvals & Certifications
- CE BS EN 61326
Communication
- Baud Rate: 19,200 bit/sec
Configuration
- USB
Electrical Connectors
- 4-Wire Ratiometric
- DIN 43880
Electrical Rating
- 5 Vdc at 59 mA, ± 0.1 V
Environmental Protection
- IP65
Filter
- 1 to 20 seconds to Reach 70 % of Final Value
Humidity
- 10 to 90 % Relative Humidity
Indication
- LED Green when Output (-0.1 to 100.1) %
- LED Red - Input/Output Error
Input
- Bridge Input: -38 to 38 mV at 5 V Excitation
- Bridge Input: -7.6 to 7.6 mV/V
Interface Connection
- USB 2, USB SpeedLink
Isolation
- Galvanic Isolation - Supply to Input to Output: 500 Vdc
Linearity
- ± 0.01 %
Load Impedance
- Bridge Impedance: 85 to 10,000 ohms (Operates with Four 350 ohms Cell in Parallel)
Materials of Construction
- Polyimide 6.6
Mounting
- DIN Rail
Operating Temperature
- -30° to 70° C (-22° to 158° F)
Output
- Output Current - Current Source/Sink: 0-21.5 mA
- Output Current Sink: Supply 10-30 Vdc
- Output Voltage - Current Drive: ± 2 mA
- Output Voltage - Range: 0-10.1 V
- Output Voltage - Range: -10.1 to 10.1 V
Power
- < 1 W Full Power
Power Supply Effect
- Output Current - Voltage Effect: 0.2 μA/V
Resistance
- Output Current - Current Source: Max.
- Output Voltage - Current Drive: Min. Load 5,000 ohms at 10 V
Response Time
- < 200 milliseconds at 10 Samples Per second
- < 50 milliseconds at 80 Samples Per second
Storage Temperature
- -30° to 70° C (-22° to 158° F)
Style
- Colour Grey
Supply Voltage
- 10-32 Vac Protected by Internal 500 mA Resettable Fuse
- 10-48 Vdc
System Requirements
- Windows® XP
Thermal Drift
- Bridge Input: < ± 0.05 %
- Output Current: 1 µA/°C
Update Time
- 10 Samples Per second
- 80 Samples Per second