HD35ED – Wireless Data Logger System

Brand: Delta OHM S.R.L.

HD35ED – Wireless Data Logger System

Brand: Delta OHM S.R.L.
HD35ED series of data loggers: the data loggers are the remote devices connected to the measuring probes.

They are installed in the environments to be monitored and are powered by the internal battery (not rechargeable) that allows a long working life.

The acquired measurements are stored in the internal memory and sent to the base unit automatically at regular intervals or upon user request. Versions with or without LCD are available.

The versions with LCD allow the measurements and the RF signal quality to be viewed also at the installation site and allow the data logger configuration through the front keyboard too.

Specifications

Pt100 / Pt1000 Measuring Range

  • -200 to +650° C

Pt100 / Pt1000 Resolution

  • 0.1° C

Pt100 / Pt1000 Accuracy

  • ± 0.1° C (excluding probe error)

Pt100 / Pt1000 Sensor Coefficient

  • a=0.00385°C-1

Pt100 / Pt1000 Connection

  • 2, 3 or 4-Wires

Thermocouple Type

  • K, J, T, N, E.
  • The inputs are not isolated, use thermocouples with isolated hot junction

Thermocouple Measuring Range

  • Type K: -200 to +1370° C
  • Type T: -200 to +400° C
  • Type E: -200 to +750° C
  • Type J: -100 to +750° C
  • Type N: -200 to +1300° C

Thermocouple Accuracy (Excluding Probe Error)

  • Type K: ± 0.1° C (600° C)
  • Type J: ± 0.1° C
  • Type T: ± 0.1° C
  • Type N: ± 0.1° C (600° C)
  • Type E: ± 0.1° C (300° C)

Thermocouple Resolution

  • 0.1° C

0/4 to 20 mA Input Shunt Resistance

  • Internal (50 W)

0/4 to 20 mA Input Resolution

  • 16 bits

0/4 to 20 mA Input Accuracy

  • ± 2 µA

0 to 50 mV, 0 to 1 V and 0 to 10 V Inputs (0 to 10 V only in HD35EDWH) Input Resistance

  • 100 MW

0 to 50 mV, 0 to 1 V and 0 to 10 V Inputs (0 to 10 V only in HD35EDWH) Resolution

  • 16 bits

0 to 50 mV, 0 to 1 V and 0 to 10 V Inputs (0 to 10 V only in HD35EDWH) Accuracy

  • ± 0.01 % Full Scale

Input for Counting the Switchings of a Voltage-Free Contact Switching Frequency

  • 50 Hz max

Input for Counting the Switchings of a Voltage-Free Contact Hold Time

  • 10 ms min.

Potentiometer

  • Typically 10 kW

Potentiometer Resolution

  • 16 bits

Potentiometer Accuracy

  • ± 0,01 % Full Scale

  • Food and Warehouses
  • Pharmaceutical, Medical Laboratories, Clean Rooms
  • Museums, Buildings and Public places
  • Air Conditioning
  • Renewable Energy
  • Agriculture and Greenhouses
  • Meteorology and Hydrology
  • Industrial Processes
show more