SPP-94 Flow Meter

Brand: SIMEX sp. z o.o.

SPP-94 Flow Meter

Brand: SIMEX sp. z o.o.
The SPP-94 flow counters are designed to work together with flow transducers equipped with analogue input.

The purpose of flow counters is to measure the instantaneous flow value and to record the total flow of media like liquids, gases or loose materials.

A wide range of total flow indication: up to 16 digits, allows controlling the flow value for a long operation time.

Thanks to the built-in batcher function the SPP-94 counters can be used in many industries like: food, pharmaceutical or paint and varnish industry.

The REL / OC control outputs can be programmed depending on the instantaneous flow value, batcher or total flow value.

Additionally the counter may be equipped with analogue outputs, according to the customer selection: active current output, passive isolated current output or active voltage output.

The counter can be configured with the local keyboard or free S-Config software via the RS-485 communication port.
Features
  • Flow Meter, Batcher, Totalizer
  • 1 Input 0/4-20 mA + 1 Programmable Function Input
  • 0, 2 or 4 REL / OC Outputs
  • Analogue Output: Active or Passive, Power Supply Output: 24V DC
  • RS-485 / Modbus RTU
  • Display of Instantaneous and the Total Flow Values
  • Batching and Counting of Doses
  • Free Configuration Software S-Config

Specifications

Number of Inputs

  • 1

Input Type

  • Current - mA

Input Levels

  • Low: 0...1V, High: 10...30 V

Output Type

  • Relay I=1A, U=30 Vdc/250 Vac (cosø=1)
  • Open Collector: I=30 mA, U=30 Vdc, P=100 mW
  • 0/4...20 mA: active current, operating range 0...24 mA Max., load resistance 700 Ω Max., resolution 13 bit
  • 4...20 mA: passive current, isolated, operating range 2,8...24 mA Max., load resistance 600 Ω @ 24 Vdc, resolution 13 bit
  • 0/1...5 V, 0/2...10 V: active voltage, operating range 0...11 V Max., load resistance min. 2000 Ω, resolution 13 bit

Measurement Method

  • Electrical
  • Pulse

Power Supply

  • 16...35 Vac, 19...50 Vdc
  • 85..260 Vac/dc
  • 11,4...15 Vac/dc

Display

  • LED, 6 x 13 mm, Red
  • LED, 6 x 13 mm, Green

Communication Interface

  • RS-485 / Modbus RTU

Transmission Parameters

  • 1200...115200 bit/s
  • 8N1 / 8N2

Operating Temperature

  • 0...+50° C
  • -20…+50° C

Protection Class

  • IP 20: Case and Connection Clips
  • IP 65: Front
  • Optional Integrated Frame for Panel Cut-out Sealing

Case Material

  • NORYL-GFN2S E1

Mounting

  • Panel

Case Dimensions

  • 96 x 48 x 100 mm

Documentation

show more