DO9785T – pH or mV Configurable Transmitters
Brand: Delta OHM S.R.L.DO9785T – pH or mV Configurable Transmitters
Brand: Delta OHM S.R.L.DO9785T pH transmitters convert the output of a pH electrode, with temperature compensation, into a 4÷20 mA signal.
The transmitter is completely configurable and suitable for panel mounting.
Dimensions 96 x 96 mm with dual LCD (measurement + temperature), output 4…20 mA insulated with 2 wires passive or 4 wires active.
Power supply in active mode 24 Vac, on request 230 Vac, in passive mode 10…35 Vdc.
The pH electrode input circuit is galvanically insulated against the 4÷20 mA output signal.
The LCD indicator allows viewing of the process signal value and of the various parameters.
The accurate design and choice of components make the instrument precise and reliable for a long working life.
The instrument works with a pH electrode or Redox and a temperature probe (Pt 100 sensor, 100 Ω at 0°C).
Contact us for more information or a quotation
Specifications
Brand
Combined Electrode Input
- pH: -1.00 pH…15.00 pH (-500…+500 mV)
- ORP: -1999…+1999 mV
- Input: impedance > 10^12 Ω
- Cable length: < 50 meters screened (about 5 nF)
- Accuracy: 0.1 % of Reading ± 1-Digit ± 0.01 % of pH per °C of temperature drift
Temperature Input
- Pt100 2/4-Wires: -50…199.9° C
- Transducer energizing: 0.5 mA DC
- Cable length: < 10 metres unscreened < 50 metres screened (about 2 nF)
- Accuracy: 0.2° C ± 0.1 % of Reading ± 0.01° C/°C
pH Electrode Temperature Compensation
- Automatic: According to Nernst
- Manual: -50…200° C
Current Output
- 4…20 mA: Programmable and proportional to the pH or mV value
- Accuracy: 0.5 % of Reading ± 0.02 mA
- Insulation: 2500 Vac 1 minute
R Load
- Load resistance: RLmax = Vdc-10/0,022 RLmax= 636 Ω @ Vdc = 24 Vdc
Relay Output
- A and B: Bistable, contact 3 A/230 Vac free potential
Power Supply
- Active: 24 or 230 Vac -15/+10 % 1 VA, 48…62 Hz
- Passive: 4…20 mA, 2-Wire configuration, 10…35 V
Housing DO9785T
- External dimensions: 96 x 96 x 126 mm
- Protection class: IP54
Housing DO9765T
- External dimensions: 120 x 122 x 56 mm wall mounting
- Protection class: IP64
Displaying prices & availability for Virginia, United States in EUR. Change location or currency.
Models matching criteria: 14
Out of Stock
Temperature Probe For Industrial Use, Pt100 Sensor, Shaft Ø6 x 45 mm.
Out of Stock
Temperature Probe With Pt100 Sensor, DIN B Head, Stem Length 600 mm.
Out of Stock
Out of Stock
Combined Industrial Electrode, S7 PG13.5 Connector, Glass Body, Ag/ AgCl Sat KCl Ø 12 x 120 mm, Temperature 0…130°C.
Out of Stock
Combined Industrial Electrode, S7 ¾” NPT Connector, Rytron Body, Ag/ AgCl Sat KCl, Temperature 0…100°C
Out of Stock
Platinum Electrode For Redox Measurement, Connector S7 PG13.5 Pressure 6 Bar, Glass Body, Ag/AgCl Sat KCl.
Out of Stock
Platinum Electrode For Redox Measurement, Rytron Body, S7 ¾” NPT Connector, Ag/AgCl Sat KCl
Out of Stock
5 m Extension Cable For Connecting The Electrode To The Transmitter. S7 On One Side, Wires On The Other Side.
Out of Stock
10 m Extension Cable For Connecting The Electrode To The Transmitter. S7 On One Side, Wires On The Other Side.
Out of Stock
Out of Stock
Extension Cable For Connecting The Electrode To The DO9785 (BNC-S7) L = 1.5 m.
Out of Stock
Out of Stock
20 m Extension Cable For Connecting The Electrode To The Transmitter. S7 On One Side, Wires On The Other Side.
Out of Stock