Accuracy
- ± 10 µV ± 0.07 % of Reading
- ± 5 µA
- 0.01 % of Full Range Input ± 0.07 % of Reading
- 0.04 % of Full Range Input ± 0.04 % of Reading or 0.5° C (0.9° F) whichever is greater
- 0.1 % of Full Range Input
Approvals & Certifications
Current
- RTD Excitation Current: 300-500 µA
Humidity
- 0 to 95 % Relative Humidity, Non-Condensing
Input
- -10 to 75 mV
- High: 20.5 mA
- Low: 3.8 mA
Isolation
- Input/Output Breakdown Isolation: 500 Vac
Linearization
- RTD: BS 1904
- RTD: BS EN 60751
- RTD: DIN 43760
- RTD: JISC 1604
- Thermocouple: BS 4937
- Thermocouple: BS EN 60584-01
- Thermocouple: IEC 584-1
Operating Temperature
- -40° to 85° C (-40° to 185° F)
Output
- 4-20 mA
- Maximum
- Minimum 3.75 mA
Power Supply Effect
- Supply Voltage Effect: 0.2 µA/V
Resistance
- Input Sensors: 18 to 390 ohms
- Maximum
RTD Type
- 3-Wire Potentiometer
- Ni100
- Pt100
Sensor, Probe Type
- E Thermocouple
- J Thermocouple
- K Thermocouple
- L Thermocouple
- N Thermocouple
- RTD
- R Thermocouple
- S Thermocouple
- T Thermocouple
Span - Minimum
- 100° C (212° F)
- 25° C (77° F)
- 5 mV
- 5 % of Full Range Input
- 50° C (122° F)
Storage Temperature
- -50° to 85° C (-58° to 185° F)
Temperature Effect
- Cold Junction: ± 0.5° C (± 0.9° F) Tracking 0.05° C/°C Range -40° to 85° C (-40° to 185° F)
Temperature Range
- Cold Junction: -40° to 85° C (-40° to 185° F)
- Thermocouple: -200° to 1,370° C (-328° to 2,498° F)
Thermal Drift
- 1 µA/°C
- Span: 0.01 %/°C
- Zero: 0.005 % of Span/°C
- Zero: 0.008° C/°C
Time Constant
- 0.5 second (to 90 % of Final Value)
Update Time
- Warm-Up: 120 seconds to Full Accuracy