
Images are representations only.
Testo 440 - Lux Kit
Brand: Testo
Kit for measuring the illuminance in workplaces, for example in offices or in production areas.
Keep the Testo 440 air velocity and IAQ measuring instrument and a lux probe safely stowed away in the case. So you can get down to work straight away!
Features- Intuitive: clearly structured measurement menu for long-term measurement and determination of illuminance according to the V-lambda curve , thus for all common light sources
- Precise: standard-compliant accuracy according to DIN EN 13032-1 and class C according to DIN 5032-7
- Convenient: non-slip probe contact surface for convenient positioning at the measuring location, internal data storage and USB port for data export
- As multifaceted as your challenges themselves: the air velocity and IAQ measuring instrument can be expanded with a large portfolio of digital probes
Specifications
Brand
Delivery Scope
- Testo 440 Air Velocity and IAQ Measuring Instrument, 3 AA Batteries, USB Cable, and Calibration Protocol (0560 4401)
- Basic Case for Testo 440 and 1 Probe
- Lux probe with fixed cable (cable length 1.4 m) and calibration protocol (0635 0551)
Temperature - NTC
- Measuring Range: -40.0°F to 302.0°F / -40°C to +150°C
- Accuracy: ±0.7°F (-40°F to -13.2°F) / ±0.4°C (-40°C to -25.1°C) | ±0.5°F (-13°F to 166.8°F) / ±0.3°C (-25°C to +74.9°C) | ±0.7°F (167°F to 211.8°F) / ±0.4°C (+75°C to +99.9°C) | ±0.5 % of mv (Remaining Range)
- Resolution: 0°F / 0.1°C
Temperature - TC Type K (NiCr-Ni)
- Measuring Range: -328.0°F to 2498.0°F / -200°C to +1370°C
- Accuracy: ±(0.5°F + 0.3 % of mv) / ±(0.3°C + 0.3 % of mv)
- Resolution: 0.1°F / 0.1°C
Weight
- 8.8 oz. / 250 g
- 110 g
Dimensions
- 6.1 x 2.6 x 1.3 in. / 154 x 65 x 32 mm
- 110 x 55 x 22 mm
Operating Temperature
- -4.0°F to 122.0°F / -20°C to +50°C
- 0 to +50 °C
Connectable Probes
- 1 x Digital Probe with Cable or 1 x Temperature NTC TUC
- 1 x Digital Bluetooth Probe or Testo Smart Probe
- 1 x Temperature TC Type K
Product Colour
- Black/Orange
- Black
Battery Type
- 3 x AA 1.5 V
Battery Life
- 12 h (Typically Vane Measurement)
Interface
- Bluetooth®; USB
Storage Temperature
- -4.0°F to 122.0°F / -20°C to +50°C
Cable Length
- 1.4 m
Light
- Measuring Range: 0 to 100000 Lux | 0 to 9300 ftc
- Accuracy: DIN 13032-1 Appendix B | F1 = 6 % = V(Lambda) Adjustment | F2 = 5 % = cos-true Evaluation | Class C according to DIN 5032-7
- Resolution: 0.1 Lux ( 10000 )
- Convenience and Maximum Flexibility for Duct and Outlet Measurements
- Long-term Monitoring of Indoor Air Quality
- Turbulence Measurement in Accordance with EN ISO 7730 / ASHRAE 55
- Range of Probes for Cleanrooms and Laboratories