Wind Speed Measuring Range
Wind Speed Accuracy
- ± 0.2 m/s or ± 2 %, the greatest (0 to 35 m/s), ± 3 % (> 35 m/s)
Wind Direction Measuring Range
Wind Direction Resolution
Compass Measurement Range
Air Temperature Measuring Range
Air Temperature Resolution
Air Temperature Accuracy
- ± 0.15° C ± 0.1 % of measurement
Relative Humidity Measuring Range
Relative Humidity Resolution
Relative Humidity Accuracy (@ T = 15…35° C)
- ± 1.5 % RH (0 to 90 %RH), ± 2 %RH (remaining range)
Relative Humidity Accuracy (@ T = -40…+60° C)
- ± (1.5 + 1.5 % of measurement) %RH
Barometric Pressure Sensor
Barometric Pressure Measuring Range
Barometric Pressure Resolution
Barometric Pressure Accuracy
Solar Radiation Measuring Range
Solar Radiation Resolution
Solar Radiation Accuracy
- Pyranometer Spectrally Flat Class C
Power Supply
- 20 W solar panel integrated charger
Backup Battery
- 12 V / 3.4 Ah lead-acid rechargeable battery
Wind Speed Averaging Interval
- Configurable from 1 second to 10 minutes
Cable Connection
- Equipped with Plug-&-Play connectors
Operating Temperature
- -40° to +70° C
- Minimum temperature for the rainfall sensor 1° C
Case
- Plastic material. Metal parts: AISI 316
Measuring Interval
- 1, 2, 5, 10, 15, 30 seconds
- 1, 2, 5, 10, 15, 30, 60 minutes
Logging Interval
- 1, 2, 5, 10, 15, 30 seconds
- 1, 2, 5, 10, 15, 30, 60 minutes
Internal Memory
- Circular management or stop logging if memory is full.
- Number of samples: > 240,000