SEM1700 Signal Conditioner
Brand: Status InstrumentsSEM1700 Signal Conditioner
Brand: Status InstrumentsThe SEM1700 is a new generation DIN rail mounted universal signal conditioner from Status Instruments.
It has been designed to accept most common process and temperature sensor inputs and provide the user with a programmable current or voltage output signal plus dual relays with a programmable delay function.
Isolation is provided between input, outputs and supply.
All temperature ranges are linear to temperature.
Both input and output loop excitation is provided as well as a fully universal power supply.
Features- Rtd, Thermocouple, mV, V, mA and Potentiometer Input
- Isolated Universal Voltage or Current Output
- Dual C/O Relay Trip Outputs
- Universal Power Requirement 22 to 250V AC or DC
- Powers Both Input And Output Current Loops
- SIL Approval
- View Live Data On An Android Phone Or Tablet
Specifications
Brand
Accuracy
- ± 0.04 % + (0.1 % of Full Scale Range) - Process Inputs (1 Reading/second) at 20° C (68° F)
- ± 0.1 % + (0.1 % of Full Scale Range) - Process Inputs (4 Readings/second) at 20° C (68° F)
- ± 0.15° C (± 0.27° F) + (0.05 % of Full Scale Range) - RTD (1 Reading/second)
- ± 0.2 % + (0.1 % of Full Scale Range) - Process Inputs (10 Readings/second) at 20° C (68° F)
- ± 0.5° C (± 0.9° F) + (0.1 % of Full Scale Range) - Thermocouples (1 Reading/second), RTD (4 Readings/second)
- ± 1° C (± 1.8° F) + (0.1 % of Full Scale Range) - Thermocouples (4 Readings/second), RTD (10 Readings/second)
- ± 2° C (± 3.6° F) + (0.1 % of Full Scale Range) - Thermocouples (10 Readings/second)
- Cold Junction Accuracy: ± 0.5° C (± 0.9° F)
- Cold Junction Tracking: ± 0.05° C (± 0.09° F)
Approvals & Certifications
- CE Tested to BS EN 61326, BS EN 61010_1
- GOST
- IEC
Calibration
- Current Output: ± 5 µA
- Voltage Output: ± 5 mV
Communication
- USB
Configuration
- Push Button
Current
- Maximum
- RTD Excitation Current: < 1 mA
Damping Adjustment
- 0 to 250 seconds, Programmable Rise & Fall for a 0-10 V Swing (Voltage Output) / 0-20 mA (Current Output)
Delay Time
- 0 to 250 seconds, Programmable ON/OFF for Each Relay
Electrical Protection
- Overvoltage
- Reverse Polarity
Electrical Rating
- 240 Vac RMS at 1 A, Resistive Load
- 30 Vdc at 1 A, Resistive Load
Humidity
- 10 to 95 % Relative Humidity, Non-Condensing
Indication
- LED
Input
- Process Input: ± 25 mA - Max.
- Process Input: 1 V - Range: ± 1 V, Max.
- Process Input: 10 V - Range: ± 10 V, Max.
- Process Input: 200 mV - Range: ± 200 mV, Max.
- Process Input: 50 mV - Range: ± 50 mV, Max.
Input Impedance
- 1 Megaohm - Voltage Input Impedance & for Thermocouple
- 20 ohms - Current Input Impedance
Isolation
- Galvanic Isolation: 3,750 V to Supply & Relays
- Galvanic Isolation: 500 V to Input/Output
Load
- Minimum: 10 kiloohms
- Sink Mode Loop Load: 600 ohms at 24 V, Max.
- Source Mode Loop Load: 550 ohms, Max.
Mounting
- DIN Rail
Operating Temperature
- -20° to 70° C (-4° to 158° F)
Output
- 0-10 V (Voltage)
- 0-20 mA (Current)
- 4-20 mA (Current)
Power
- 3 W, Max.
Range
- Process Input: ± 25 mA - Max.
- Process Input: ± 50 mV- ± 10 V, Max.
Resistance
- 20 ohms, Max.
Resolution
- 1 Readings/second (16-bits)
Response Time
- < 500 milliseconds to Reach 95 % of Final Value
RTD Type
- Cu100
- Cu53
- Ni100
- Ni120
- Pt100
Sensitivity
- Supply Sensitivity: Supply Ripple Rejection < ± 5 µA Error at 1 V RMS 50 Hz Ripple
Sensor, Probe Connection
- 2-Wire
- 3-Wire
Sensor, Probe Type
- B Thermocouple
- C(W5) Thermocouple
- D(W3) Thermocouple
- E Thermocouple
- G(W) Thermocouple
- J Thermocouple
- K Thermocouple
- L Thermocouple
- N Thermocouple
- R Thermocouple
- S Thermocouple
- T Thermocouple
- U Thermocouple
Span & Zero Adjustments
- ± 10 % of Span & Zero
Stability
- ± 0.015 % of Full Scale Reading/°C - Input Typical: Pt100, Ni 100, Ni 120, Cu 100, Cu 53
- ± 0.025 % of Full Scale Reading/°C - Process Input: ohms
- ± 0.04 % of Full Scale Reading/°C - Process Input: 50 mV, 200 mV, 1 V, 10 V, mA
- ± 0.05 %/°C - Process Input: Slide Wire
- ± 0.05 % of Full Scale Reading/°C - Input Typical: K, J, E, C(W5), D(W3), G(W)
- ± 0.08 % of Full Scale Reading/°C - Input Typical: N, L, U
- ± 0.10 % of Full Scale Reading/°C - Input Typical: R, S, B
- ± 0.15 % of Full Scale Reading/°C - Input Typical: T
- Current Output: ± 5 μA/°C
- Output Voltage: ± 1 mV/°C
Storage Temperature
- -40° to 85° C (-40° to 185° F)
Supply Voltage
- 11-30 Vdc, 24 V Nominal - Supply in Sink Mode
- 20-240 Vac, 50/60 Hz
- 20-240 Vdc
Temperature Effect
- 0.015° C/ohms - RTD Lead Effect
Temperature Range
- -200° to 2,300° C (-328° to 4,172° F)
- Cold Junction: -20° to 70° C (-4° to 158° F)
Turn-On Time
- Start Up Time: < 3 seconds
Voltage
- Input: ± 1 V
- Input: ± 10 V
- Input: ± 200 mV
- Input: ± 50 mV
- Output: 0-10 V