Thermal Microclimate Data Logger

Price
Request a Quote
Stock
Out of Stock

Specifications

Dimensions (Length x Width x Height)

  • 220 x 180 x 50 mm

Weight

  • 1100 g (with batteries)

Materials

  • ABS
  • Polycarbonate
  • Aluminium

Display

  • Backlit, dot matrix
  • 128x64 dots, visible area 56x38 mm

Operative Temperature

  • -5° to 50° C

Storage Temperature

  • -25° to 65° C

Operative Relative Humidity

  • 0 to 90 % RH non condensing

Protection Class

  • IP64

Instrument Uncertainty

  • ± 1-Digit @ 20° C

Mains Adapter (Code SWD10)

  • 12 Vdc/1A

Batteries

  • Four 1.5V batteries size C-BABY

Autonomy

  • With temperature and RH probes: 200 hours with 7800 mAh alkaline batteries
  • With hotwire probe @ 5 m/s: 100 hours with 7800 mAh alkaline batteries

Power Absorbed with Instrument Off

  • < 45 µA

Security of Stored Data

  • Unlimited

Atmospheric Pressure Measurement with Inbuilt Sensor Accuracy

  • ± 0.5hPa

Atmospheric Pressure Measurement with Inbuilt Sensor Resolution

  • 0.1hPa

Atmospheric Pressure Measurement with Inbuilt Sensor Response Time

  • 1 s

Temperature Measurement with Instrument Pt100 Measuring Range

  • -200…+650° C

Temperature Measurement with Instrument Resolution

  • 0.01° C in the range ± 199.99° C, 0.1° C outside this range

Temperature Measurement with Instrument Accuracy

  • ± 0.01° C in the range ± 199.99° C, ± 0.1° C outside this range

Temperature Measurement with Instrument Temperature Drift at 20° C

  • 0.003 %/°C

Temperature Measurement with Instrument Drift After 1 Year

  • 0.1° C/year

Instrument Relative Humidity Measurement Measuring Range

  • 0 to 100 %RH

Instrument Relative Humidity Measurement Resolution

  • 0.1 %RH

Instrument Relative Humidity Measurement Accuracy

  • ± 0.1 %RH

Instrument Relative Humidity Measurement Temperature Drift at 20° C

  • 0.02 %RH/°C

Instrument Relative Humidity Measurement Drift After 1 Year

  • 0.1 %RH/year

Input for Probes with SICRAM Module

  • 8 Male 8-Pole DIN 45326 connectors

RS-232C Serial Interface Type

  • Galvanically isolated RS-232C

Baud Rate

  • Configurable between 1200 and 38400 baud

Data Bit

  • 8

Parity

  • None

Stop Bit

  • 1

Flow Control

  • Xon/Xoff

Serial Cable Length

  • Maximum 15 m

USB Interface Type

  • 1.1 - 2.0 galvanically isolated

Memory

  • Divided in 64 blocks

Storage Capacity

  • 67600 storages of 8 inputs each

Storage Internal

  • To select between: 15, 30 seconds, 1, 2, 5, 10, 15, 20, 30 minutes and 1 hour

Printing Internal

  • To select between: 15, 30 seconds, 1, 2, 5, 10, 15, 20, 30 minutes and 1 hour

show more