
Images are representations only.
Panel Mount Digital Indicator
Price
176,50 €EUR
Stock
Request Lead Time
Specifications
Brand
Accuracy
- 0.05 % of Full Scale (Process Indicator)
- Cold Junction Error: ± 0.5° C (± 0.9° F) (Universal Temperature Indicator)
- Cold Junction Tracking: 0.05° C/°C (Universal Temperature Indicator)
- Isolated Re-Transmission: 0.07 % of Full Scale
Approvals & Certifications
- Electrical Safety: UL BS EN 61010-1, Flammability: UL 94VO
- EMC BS EN 50081-1 (Emissions), BS EN 50082-2 (Susceptibility)
- Flammability: IEC 707 FV0
Consumption
- 6 VA, Max.
Current
- 0-20 mA (Process Indicator)
- Excitation Current: 300-550 µA (Universal Temperature Indicator)
- Ripple Current: < 3 µA
Display
- 4-Digit Red LED (14.2 mm High/High Intensity)
- -999 to 9,999
Electrical Connectors
- Termination: Screw Terminal
Electrical Contacts
- 2 x Changeover Relays Common Wiper
Environmental Protection
- Sealing: Panel IP65
Excitation Voltage
- 24 V ± 5 % at 50 mA (Process Indicator)
Humidity
- 10 to 90 % Relative Humidity, Non-Condensing
Indication
- 4 Alarm Red LED Indicators 2.5 mm High Numeric
Input Impedance
- Current: 47 ohms (Process Indicator)
- Voltage: 1 Megaohm (Process Indicator)
Isolation
- 500 Vac: Breakdown Isolation, Input/Output RMS (Galvanically Isolated)
Linearization
- Linear (Process Indicator)
- Square Root (Process Indicator)
Load
- Maximum
Materials of Construction
- ABS/Polycarbonate
Measurement Accuracy
- RTD: 0.1° C (32.18° F) ± 0.05 % of Reading (Universal Temperature Indicator)
- Thermocouple: ± 0.04 % of FRI ± 0.04 % of Reading or 0.5° C (0.9° F), whichever is greater (Universal Temperature Indicator)
Operating Temperature
- -30° to 60° C (-22° to 140° F)
Output
- 0 to 23 mA
Output Load
- 1 Kiloohm
Power
- AC - Max.
- DC - Max.
Power Supply
- S1: 90-253 Vac, (50/60 Hz)
- S2: 20-35 Vdc
Power Supply Effect
- Voltage Effect: 0.2 μA/V
Resistance
- Maximum
- Sensor: 18 to 390 ohms (Universal Temperature Indicator)
Resistance Effect
- Lead Resistance Effect: 0.002° C/ohms (Universal Temperature Indicator)
RTD Type
- Pt100
Sensor, Probe Type
- E Thermocouple
- J Thermocouple
- K Thermocouple
- L Thermocouple
- N Thermocouple
- RTD
- R Thermocouple
- S Thermocouple
- T Thermocouple
Stability
- 1 µA/°C
Storage Temperature
- -50° to 85° C (-58° to 185° F)
Supply Voltage
- 0-10 V (Process Indicator)
- Maximum
Temperature Range
- Cold Junction Range: -30° to 60° C (-22° to 140° F) (Universal Temperature Indicator)
- Sensor: -200° to 850° C (-328° to 1,562° F) (Universal Temperature Indicator)
Thermal Drift
- Span: 0.01 %/°C
- Zero: 0.008° C/°C (Universal Temperature Indicator)
- Zero: 0.1 µV/°C
Time Constant
- Filter Off: < 1 second (to 63 % of Final Value)
Update Time
- 250 milliseconds, Max.
- Warm-Up Time: 120 seconds to Full Accuracy
Voltage
- Maximum
Documentation
Similar SKUs

DM3430/S*
DM3430 Current & Voltage Panel Meter
Status Instruments
187,50 €EUR
Out of Stock
Panel Mount Digital Indicator

DM4500U/S*
DM4500U Panel Meter
Status Instruments
217,10 €EUR
Out of Stock
Panel Mount Digital Indicator

DM4500F/S*
DM4500F Panel Meter
Status Instruments
217,10 €EUR
Out of Stock
Panel Mount Digital Indicator

PD941-8K9-15
PD900 Series ConSolidator Multi-Channel Controller
Precision Digital
Request a Quote
Out of Stock
PRECISION DIGITAL 4 Input, Panel Mount

PDX9000EC
PDX9000 ConsoliDator+ Mount Conversion Kit
Precision Digital
Request a Quote
Out of Stock
PRECISION DIGITAL Enclosure for Field-Mount ConsoliDator+ (Only for Conversion from Panel-Mount)

PDA6018
Panel Mounting Kit for PD6402
Precision Digital
Request a Quote
Out of Stock
Panel Mounting Kit for PD6402

PDX9000FC
PDX9000 ConsoliDator+ Mount Conversion Kit
Precision Digital
Request a Quote
Out of Stock
PRECISION DIGITAL Front Cover for Panel-Mount ConsoliDator+ (Only for Conversion from Field-Mount)

PDA1000
PDA1000 Panel Mount Buzzer and Light
Precision Digital
Request a Quote
Out of Stock
Panel Mount Buzzer and Light