DM4500F/S*

Series: DM4500F Panel Meter Brand: Status Instruments

Panel Mount Digital Indicator

Price
217,10 €EUR
Stock
Request Lead Time
Does not ship to OH, United States

Specifications

Accuracy

  • 0.005 % - Frequency/Tachometer
  • 0.01 % - Chronometer
  • 0.1 % of Full Scale ± 1-bit: OPT4500/MA & OPT4500/V Output (mA/V Option)

Approvals & Certifications

  • UL 94 V-0

Communication

  • RS-485

Consumption

  • 10 W, Max.
  • 5 W (without Options) - Power

Current

  • 5 A, Max.
  • 8 A, Max.
  • Ioff: > 3 mA DC (NAMUR)
  • Ion: < 1 mA DC (NAMUR)
  • Leakage: 100 µA, Max.
  • Maximum

Display

  • Counter Limits: -99999 to 99999
  • LED Display - 5 Programmable Tricolor 14 mm Digits

Duty Cycle

  • FC with 30 % Contact Enclosure Filter for 10 Hz
  • FC with 50 % Contact Enclosure Filter for 20 Hz

Enclosure, Body Material

  • Polycarbonate (UL 94 V-0)

Environmental Protection

  • IP65

Excitation Voltage

  • 18 Vdc at 100 mA (Not Stabilized)
  • 24 Vdc at 30 mA
  • 8 Vdc at 30 mA

Frequency

  • 0.01 Hz to 20 kHz / 10 kHz (Totalizer)
  • 15 kHz: Up or Down with Relays, Bi-Directional Phase or Direct with Relays & Bi-Directional Indepedent with Relays (Counter)
  • 20 kHz: Up or Down without Relays, Bi-Directional Phase or Direct without Relays & Bi-Directional Independent without Relays (Counter)
  • 50/60 Hz
  • Maximum
  • Minimum: 0.01 Hz

Function

  • Totalizer Display

Humidity

  • < 95 % Relative Humidity, Non-Condensing

Input

  • NPN/PNP

K-Factor

  • Scale Factor Counter, Frequency / Tach: Programmable from 0.0001 to 99999

Load

  • ≤ 500 ohms, Max.
  • ≥ 10 kiloohms, Max.

Operating Temperature

  • -10° to 60° C (14° to 140° F)

Output

  • 0-10 V
  • 4-20 mA

Power

  • 1,250 VA / 150 W, Max.
  • 10.5-70 Vdc: DM4500/S2
  • 100-300 Vdc: DM4500 / S1
  • 2,000 VA / 192 W, Max.
  • 22-53 Vac: DM4500/S2
  • 85-265 Vac: DM4500/S1

Programming

  • Decimal Point
  • Front Panel Buttons

Relay Output

  • 2 Relays
  • 4 Relays

Resistance

  • Contact: Max.

Resolution

  • 13-bits: OPT4500 / MA & OPT4500 / V Output (mA/V Option)
  • 5-Digits - Frequency Meter & Pulse Counter
  • 8-Digits - Totalizer Function Resolution Displayed in 2 Parts

Response Time

  • 0.1 to 9.9 seconds Programmable - Frequency/Tachometer
  • 50 milliseconds: OPT4500 / MA & OPT4500 / V Output (mA/V Option)

Sensitivity

  • > 120 mVpp at > 1 kHz - Input (2-Channels) Magnetic Pickup
  • > 60 mVpp at 60 mVpp at < 1 kHz - Input (2-Channels) Magnetic Pickup

Sensor, Probe Type

  • NAMUR Sensor

Storage Temperature

  • -25° to 85° C (-13° to 185° F)

Switch Type

  • NPN
  • PNP
  • SPDT
  • SPST

Temperature Coefficient

  • 50 ppm/°C

Thermal Drift

  • 0.2 mV/°C: OPT4500/V Output (mA/V Option)
  • 0.5 µA/°C: OPT4500 / MA Output (mA/V Option)

Turn-On Time

  • Switching Time: 1 millisecond, Max.
  • Switching Time: Max.

Update Time

  • 100 milliseconds - Counter & Chronometer
  • Warm Up Time: 5 minutes

Voltage

  • 0 2.6 Vdc: TTL / 2.4 Vdc (Encoder) Logic Levels & NPN or PNP Logic Levels
  • 250 Vac / 150 Vdc, Max.
  • 277 Vac / 125 Vdc, Max.
  • 5 V, 3.9 K, 20 Hz: Contact Closure
  • High Input (1-Channel): 10-300 Vac
  • Maximum

show more